The Problem

A customer of Tripar had been buying the Reduced Airflow IC Box, but discovered that it did not meet the maximum airflow requirements of a state specification.

In this case this was the Florida Building Code, which prescribes 2 CFM max airflow at a negative pressure of 75 Pascals. Since then, similar airflow restrictions have been imposed in many jurisdictions.
Triparโ€™s technical specialists analyzed the problem. They saw that the integral junction box used on these IC boxes was already gasketed and had knockouts of the โ€œpress-backโ€ type that also did not contain screwdriver slots, meaning that the leakage was elsewhere.

The Solution

Analysis showed excess airflow coming from two places:

  • Joints within the box itself were overlapping, but there remained infinitesimal gaps over the length of the seams.
  • The plaster frame was riveted to the IC Box both on the top and on two long edges, but the interface between the two was insufficient.

Triparโ€™s engineers attacked both sources of excess airflow by:

  • Applying a caulking to all interior joints of the IC Box.
  • Applying a gasket to the perimeter of the underside of the plaster frame where it contacted the riveted IC Box.

Samples were submitted to the customer, which easily passed the prescribed airflow test.

The Result

Tripar has successfully promoted and sold thousands such I.C.Boxes and plaster frames to multiple clients, coining the term โ€œUltra-Airtightโ€, indicating that they meet extremely stringent airflow requirements.

Tripar had airflow tests performed on the Ultra-Airtight I.C.Boxes by an independent and certified lab and ย passed with flying colors, obtaining airflow rates of under 0.2 cfm (10% of the 2 cfm permissible!)

To obtain more information about the Ultra Airtight I.C. Boxes and see the Test Report please visit our New Product Bulletin

[rev_slider alias=”cta-contact”]

Continue Reading

You also may be interested in the following articles

The Shutter lighting plaster frame

The Shutterโ„ข: A Universal Plaster Frame

Finally, a universal plaster frame to rule them all
Read Article

The Benefits of UL1598 Standard Assemblies

Saving our client $100,000+ with our standard assemblies
Read Article

Reshoring Bar Hangers Back to Canada

A US-based OEM reshoring 20K+ bar hangers
Read Article

Looking for specific information or need a custom product built?

Contact us today and one of our representatives will get back to you with a free quote.